Get All You Need

Bci Joist Hole Chart


Here's more information on cutting round holes as well as some Do's and Don'ts regarding holes in BCI® and AJS® Joist webs. When you're out in the field and need to cut a hole in an I-Joist, the Allowable Hole Table and details in our Western and Eastern Specifier Guides explain where holes of a specific size may be placed. These hole. BC Calc performs engineering analysis to help our customers size beams, joists, columns, studs and tall walls for their building projects. It is simple to use, yet flexible enough to analyze a variety of common applications. The user enters the member geometry, adds loads, holes and other relevant data and then selects a product for analysis.


BCI Door & Window Header Load Table - IJ-9: Tech Note: View: tech-note: us-east us-west: BCI Joist Span to Depth Ratio in BC Calc - IJ-2: Tech Note: View: tech-note:. Rounded Rectangular Web Holes in BCI Joists - IJ-33: Tech Note: View: tech-note: us-east us-west: Temperature and Moisture Content of Engineered Wood Products During. - BCI® 5000 rim joist: 2-10d box nails, one each in the top and bottom flange. - BCI® 6000, 60 rim joist: 2-16d box nails, one each in the top and bottom flange. - BCI® 6500, 90 rim joist: Toe-nail top flange to rim joist with 2-10d box nails, one each side of flange. • BCI ® rim joist, rim board or BCI blocking panel to support.

Bci Joist Hole Chart www inf inet com

Find the correct span and size for BCI Joists and Versa-Lam LVL based on your region and application. Download specifier and install guides, or use BC Calc software to perform engineering analysis.


Attached to the bottom flange of the joists through the first layer using 15/8 inch (41mm) Type W drywall screws spaced at 12 inches (305mm) on center on intermediate joists and 6 inches (152mm) on center at end joints. The longitudinal joints of this layer must be offset 24 inches (610mm) from those of the base layer.


Slo e Factor Table LH - Horizontal Span Length BCI/AJS Joist Depth C = High End Cut Length 18" 0.25 0.38 0.50 0.63 0.75 0.88 1 .00 1.13 1 .25 1 .50 20" 0.28 0.42 0.56 0.70 0.84 0.98 ft 16" 0.23. BCI Joists - Technical Notes Author: Boise Cascade Corporation Subject: Technical Notes for BCI Joists


Western US BCI® and VERSA-LAM® Installation Guide (Letter size) Western US Commercial Guide (Including Glulam Beams) Boise Glulam Beam and Specifier Guide. EASTERN US - For I-Joist and LVL lumber products manufactured in Alexandria, Louisiana; Thorsby, Alabama; and St. Jacques, New Brunswick. Eastern US BCI® and VERSA-LAM® Specifier Guide.


BCI®Joists are specially constructed I-joists with flangers made from strong VERSA-LAM® laminated veneer lumber with orienting strand board web and approved waterproof structural adhesive, supplying outstanding strength and permanence. Learner more about BCI® Joists and our sizing software BC Calc® or view the WHAT East and OURS Western span the size charts.


BCI® Joists Light in weight, but heavy­duty, BCI® Joists have a better strength / weight ratio than dimension lumber. Knockouts can be removed for cross­ventilation and wiring. Ceilings Framed with BCI® Joists ®The consistent size of BCI Joists helps keep gypsum board flat and free of unsightly nail pops and ugly


- BCI® 4500s, 5000s rim joist: 2-10d box nails, one each in the top and bottom flange. - BCI® 6000s, 60s rim joist: 2-16d box nails, one each in the top and bottom flange. - ®BCI 6500s, 90s rim joist: Toe-nail top flange to rim joist with 2-10d box nails, one each side of flange. • ®BCI rim joist, rim board or BCI ® blocking panel.


furnishing and installation of all BCI ® Joists . as shown on the drawings, herein specified . and necessary to complete the work. Materials: BCI ® Joists shall be manu-factured by Boise Cascade Engineered . Wood Products with oriented strand . board webs, Versa-Lam ® laminated veneer . lumber flanges and waterproof, structural adhesives.


• Table based upon published ICC evaluation reports listed on the right.. - ®Use sloped seat hangers when BCI Joist slope exceeds ¼" per foot. - ®Use sloped seat hangers and beveled web stiffeners when BCI Joist slope exceeds ¼" per foot. - Leave 1/16" clearance (⅛" maximum) between the end of the supported joist and the head of the.


There are no changes to the web hole chart in our BCI® joist literature, but there are a couple of edits that have been made to the "Large Rectangular Holes in BCI® Joists" table shown below the main web hole chart (page 7 of the Eastern Specifiers Guide).


SCI' 450Cs, hOûOs rim joist: 2-101 box nails, one each in the top and bottom flange SCP SOOOs, +0s rim joist: 2-1£d boy. nails, one each in the top and bottom flange SCI' S5U0s: 90s rim joist: I oe-nail top flange to rim joist with 2-1ûd box nails, one each side ot flange. SCI' rim joist, rim board or BCIË blocking panel to support.


Holes apply to either single or multiple joists in repetitive member conditions. For multiple holes, the amount of uncut web between holes must equal at least twice the diameter (or longest side) of the largest hole. 11⁄2" round knockouts in the web may be removed by using a short piece of metal pipe and hammer.


The BCI Series I-joists covered by this report, as described in Table 1, are made with VERSA-LAM® LVL flanges and OSB webs in accordance with the in-plant manufacturing standard approved by APA. BCI 60S and BCI 90S shall be permitted to be manufactured with proprietary ThermaxTM as described in APA Product Report PR-S201. 3. Design properties:


Support, 4.5 Holes in I-Joist Web, 4.6 Duration of Load, 4.7 In-Service Moisture Conditions, 4.8 Repetetive-Member Use, 4.9 Member Spans, 4.10 Deflection,. " min. plywood/OSB rated sheathing is glued and nailed to joists. • Table values represent the most restrictive of simple or multiple span applications.


- BCI® 6000s, 60s rim joist: 2-16d box nails, one each in the top and bottom flange. - BCI® 6500s, 90s rim joist: Toe-nail top flange to rim joist with 2-10d box nails, one each side of flange. • ®BCI rim joist, rim board or BCI® blocking panel to support: - 8d nails at 6 inches on center. - When used for shear transfer, follow.


The program helps the user identify which of Boise Cascade's engineered wood products meet the demands of the application. BCI® Joists are specially constructed I-joists with flanges made from strong VERSA-LAM® LVL (Laminated Veneer Lumber) with oriented stranded board webs and approved waterproof structural adhesives, providing outstanding.


IJ-23-US Web Armor Fire Protection for AJS/BCI Joists Installation Guide. IJ-24-US Analyzing Multiple Web Holes as a Single Encompassing Hole. IJ-25-US Mineral Wool Insulation for Fire Protection of Floors Installation Guide. IJ-26-US FireBreak Ceramic Fiber Blanket Protection for AJS/BCI Joists: Installation Guide.


BCI® Joist Hole Location & Sizing, Large Rectangular Holes 7 . . . BCI. • Table values assume minimum bearing lengths without web stiffeners for joist depths of 16" inches and less. • Floor tile will increase dead load and may require specific deflection limits,


Gallery of Bci Joist Hole Chart :

I joist Span Chart

Bci Floor Joist Span Chart Best Picture Of Chart Anyimage Org

Bci Joist Hole Chart

Bci Floor Joist Span Chart Floor Roma

Bci Joist Hole Chart - The pictures related to be able to Bci Joist Hole Chart in the following paragraphs, hopefully they will can be useful and will increase your knowledge. Appreciate you for making the effort to be able to visit our website and even read our articles. Cya ~.